Water Quality Monitoring System

Home|Water Quality Monitoring System
  • Feature
    • It adopts heat-resisting gel dielectric and solid dielectric double liquid junction structure; in the event that the electrode is not connected to the back pressure, it can withstand a max. pressure of 0.4 Mpa.
    • It can be directly used for ≤130 °C sterilization.
    • There is no need for refilling of electrolyte, therefore maintenance is low.
    • It adopts S8 or VP socket, which can be replaced by any overseas electrode.
    Application
    • thermal power plants
    • chemical fertilizer production
    • metallurgy
    • environmental protection
    • pharmacy
    • biochemical engineering
    • wastewater industry
    Contact Us
     
    Catalogue
  • Feature
    • It adopts heat-resisting gel electrode
    • It can maintain excellent precision under high temperatures and high pH values
    • There is no need for refilling of electrolyte, therefore maintenance is low.
    Application
    • industrial wastewater treatment
    • environmental protection water treatment
    • pH measurement of flue gas desulfurization
    Contact Us
     
    Catalogue
  • Feature
    • It adopts the world-class solid dielectric and a large area of PTFE liquid for junction, difficult to block and easy to maintain
    • Long-distance reference diffusion channel greatly extends the service life of electrodes in the harsh environment.
    • There is no need for refilling of electrolyte, therefore maintenance is low.
    • High accuracy, fast response and good repeatability
    Application
    • semiconductors industries
    • iron and steel industries
    Contact Us
     
    Catalogue
  • Feature
    • It adopts the world-class solid dielectric and a large area of PTFE liquid for junction, difficult to block and easy to maintain
    • Long-distance reference diffusion channel greatly extends the service life of electrodes in the environment.
    • There is no need for refilling of electrolyte, therefore maintenance is low.
    • High accuracy, fast response and good repeatability
    Application
    • pure water
    • high-purity water
    • thermal power plants (with flow cell)
    Contact Us
     
    Catalogue
  • Feature
    • It adopts PPS/PC casing and the upper and lower 3/4NPT pipe thread, so it is easy for installation and there is no need of the jacket, thus saving the installation cost.
    • The electrode adopts the high-quality low-noise cable, which makes the signal output length more than 20 meters free of interference.
    • Reference electrode with silver ions Ag/AgCL
    • There is no need for refilling of electrolyte, therefore maintenance is low.
    • High accuracy, fast response and good repeatability.
    • Proper operation shall make service life longer.
    • It can be installed in the reaction tank or pipe laterally or vertically.
    • Profile – 3in1 Electrode (Integrating temperature compensation and solution grounding)
    Application
    • water, sewages, and water treatment
    • any water bodies with common conditions
    Contact Us
     
    Catalogue
  • Feature
    • Automatic temperature compensation: It performs automatic temperature compensation when the temperature is within the range of 0~99.9℃.
    • Water proof and dust-proof design: Its protection grade is IP54. It is applicable for outdoor use.
    • Display, menu and notepad: It adopts menu operation, which is like that in a computer. It can be easily operated only according to the prompts and without guidance of the operation manual.
    • Multi-parameter display: The PH values, input mV values (or output current values), temperature, time and status can be displayed on the screen at the same time.
    Application
    • Thermal power plants
    • Chemical fertilizer production
    • Metallurgy
    • Environmental protection
    • Pharmacy
    • Biochemical engineering
    • F&B and drinking water
    • Wastewater and many other industries.
    Contact Us
     
    Catalogue
  • Feature
    • Self-cleaning function can be selected according to the use environment.
    • Stable data and reliable performance
    • Built-in self-diagnosis function to ensure accurate data.
    Application
    • sewage treatment plant
    • water plant
    • water station
    • surface water industry and other fields.
    Contact Us
     
    Catalogue
  • Feature
    • LCD display, high-performance CPU chip, high-precision AD conversion technology and SMT chip technology.
    • Multi-parameter, temperature compensation, high precision and repeatability.
    • US TI chips; 96 x 96 world-class shell; world-famous brands for 90% parts
    • The current output and alarm relay adopt optoelectronic isolating technology, strong interference immunity and the capacity of long-distance transmission.
    • Isolated alarming signal output, discretionary setting of upper and lower thresholds for alarming, and lagged cancellation of alarming.
    Application
    • Thermal power plants
    • Chemical fertilizer production
    • Metallurgy
    • Environmental protection
    • Pharmacy
    • Biochemical engineering
    • F&B and drinking water
    Contact Us
     
    Catalogue
  • Feature
    • Dissolved Oxygen Electrode applicable for Polarography Principle
    • With imported breathable membrane heads
    • Fluorine plastic, silicone, stainless steel wire mesh composite membrane.
    • Platinum cathode; Silver anode; Potassium chloride electrolyte.
    Application
    • small microbial culture reactors
    • environmental monitoring
    • wastewater treatment
    • aquaculture
    Contact Us
     
    Catalogue
  • Feature
    • Aluminum shell
    • It has a complete English display and elegant interface: Liquid crystal display module with high resolution is adopted.
    • Simple menu structure and text-type man-instrument interaction: it adopts classified menu structure, which is similar to that of a computer.
    • It is clearer and more convenient. It is not necessary to remember the operation procedures and sequences.
    • It can be operated according to the prompts on the screen without the guidance of an operation manual.
    • Multi-parameter display: The oxygen concentration value, input current (or output current), temperature values, time and status can be displayed on the screen at the same time.
    Application
    • Boiler water and condensates
    • Thermal power plants
    • Power plant desalted water
    • Places with trace oxygen
    • Sewage
    Contact Us
     
    Catalogue
  • Feature
    • Dissolved Oxygen Electrode applicable for Polarography Principle
    • High stability and reliability, which can be used in the harsh environment.
    • Less maintenance
    • Imported stainless steel grit mesh membrane
    • Ultra-resistant to pressure (0.6MPa)
    Application
    • Urban sewage treatment
    • Industrial wastewater
    • Aquaculture
    • Environment monitoring and more
    Contact Us
     
    Catalogue
  • Feature
    • The instrument has all the parameters for microcomputer storing, calculating and compensating of the related measured dissolved oxygen values; WSDO4001 can set the relevant data, such as elevation and salinity.
    • It is also featured by complete functions, stable performance and simple operation.
    • It is an ideal instrument in the field of the dissolved oxygen test and control.
    • It adopts the backlit LCD display, with error indication.
    • It has an automatic temperature compensation; isolated 4-20mA current output; the dual-relay control; high and low points alarming instructions; power-down memory; no need back-up battery; data saved for more than a
    Application
    • Thermal power plants
    • Chemical fertilizer
    • Metallurgy
    • Environment monitoring
    • Biochemical engineering etc.